Specifications
HMPB 250 LB Series Product Specifications |
|||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Part Number | Rated Loads | Stroke Length | Retracted Length | Voltage | Current Draw* | Speed* | Limit Switch | Duty Cycle* | |||
# | (lbs) N | In | mm | In | mm | in/s | mm/s | ||||
MPB3905-3 | (250) 1112 | 3 | 76 | 11.25 | 285 | 115 VAC | 2 | 0.7 | 18 | No | 23% |
MPB3905-6 | (250) 1112 | 6 | 152 | 14.25 | 362 | 115 VAC | 2 | 0.7 | 18 | No | 23% |
MPB3905-12 | (250) 1112 | 12 | 304 | 20.25 | 514 | 115 VAC | 2 | 0.7 | 18 | No | 23% |
MPB3905-12 | (250) 1112 | 18 | 457 | 26.25 | 666 | 115 VAC | 2 | 0.7 | 18 | No | 23% |
MPB4905-3 | (250) 1112 | 3 | 76 | 11.25 | 285 | 115 VAC | 1 | 0.6 | 15 | No | 21% |
MPB4905-6 | (250) 1112 | 6 | 152 | 14.25 | 362 | 115 VAC | 1 | 0.6 | 15 | No | 21% |
MPB4905-12 | (250) 1112 | 12 | 304 | 20.25 | 514 | 115 VAC | 1 | 0.6 | 15 | No | 21% |
MPB4905-18 | (250) 1112 | 18 | 457 | 26.25 | 666 | 115 VAC | 1 | 0.6 | 15 | No | 21% |
HMPB3905-3 | (250) 1112 | 3 | 76 | 11.25 | 285 | 115 VAC | 5 | 1.4 | 35 | No | 11% |
HMPB3905-6 | (250) 1112 | 6 | 152 | 14.25 | 362 | 115 VAC | 5 | 1.4 | 35 | No | 11% |
HMPB3905-12 | (250) 1112 | 12 | 304 | 20.25 | 514 | 115 VAC | 5 | 1.4 | 35 | No | 11% |
HMPB3905-18 | (250) 1112 | 18 | 457 | 26.25 | 666 | 115 VAC | 5 | 1.4 | 35 | No | 11% |
PHMPB3905-3 | (250) 1112 | 3 | 76 | 11.25 | 285 | 115 VAC | 5 | 1.4 | 35 | Yes | 10% |
PHMPB3905-6 | (250) 1112 | 6 | 152 | 14.25 | 362 | 115 VAC | 5 | 1.4 | 35 | Yes | 10% |
PHMPB3905-12 | (250) 1112 | 12 | 304 | 20.25 | 514 | 115 VAC | 5 | 1.4 | 35 | Yes | 10% |
PHMPB3905-18 | (250) 1112 | 18 | 457 | 26.25 | 666 | 115 VAC | 5 | 1.4 | 35 | Yes | 10% |
* At Rated Load |
Models
HMPB 250 lb. Series Dimensions |
---|
HMPB 250 lb. Series Wiring DiagramNote: For all AC motors, a capacitor is required. The capacitor can be supplied the customer or Duff-Norton |
---|